Product Specification
Style 1332 Single Conductor with Covering
Rating: 200 deg C, 300 Vac, Horizontal flame, Oil Resistant 80 deg C (optional), Gasoline Resistant (opt)
Conductor: 30 AWG - 10 AWG solid or stranded round.
Insulation Extruded FEP, 13 mils min average, 12 mils minimum at any point.
Covering: (Optional) Extruded FEP, 2 mils or heavier or glass braid 7 mils or heavier.
Standard: Appliance Wiring Material UL 758.
Marking: General.
Usage: Internal wiring of appliances. In addition, the tag may also indicate the following: Suitable for immersion in gasoline; gasoline vapor; 80 deg. C in oil; and or 600 volts peak for electronic use only.
OEM Specification Are Also Welcome!
Main Product
Hot Product
Company Intruction
Certification
UL Certification
More Test report (Rohs,Reach,Flame Retardant),Pls contact us
Test Equipment
Production Process
Overseas Exibition
Packing
FAQ
Q:Are you a factory or a trading company
A:ADS company is a professional cable manufacturer with 15 years production experience.
Q:What's your company MOQ
A:Our company has MOQ requirements, but we also accept small quantity.
Q:Whether these products quality assured?
A:Most of cables are certificated. Also, we have strict QC, all products are 100% tested before delivery. Quality is assured.
Q:Can you send a sample for us to test?
A:1.If we have it in stock and the amount is small, it is free.
2.If we do not have it in stock, sample and freight cost have have to be paid by your esteemed company. But we will return the sample cost to you when we receiving your initial order.
Q:If I want to purchase, how to pay?
A: Generally we do T/T in 30% deposit before production, 70% balance before loading. Also payment terms are negotiable depending on customer's request.
Contact Us
Style 1332 Single Conductor with Covering
Rating: 200 deg C, 300 Vac, Horizontal flame, Oil Resistant 80 deg C (optional), Gasoline Resistant (opt)
Conductor: 30 AWG - 10 AWG solid or stranded round.
Insulation Extruded FEP, 13 mils min average, 12 mils minimum at any point.
Covering: (Optional) Extruded FEP, 2 mils or heavier or glass braid 7 mils or heavier.
Standard: Appliance Wiring Material UL 758.
Marking: General.
Usage: Internal wiring of appliances. In addition, the tag may also indicate the following: Suitable for immersion in gasoline; gasoline vapor; 80 deg. C in oil; and or 600 volts peak for electronic use only.
Conductor | Insulation | Max.Conductor Resistance DC 20ºC Ω/km | Packing | |||
AWG | Conductor Construction No./dia.(mm) | Diameter (mm) | Insulation Thickness (mm) | Out Diameter (mm) | m/coil / | |
30 | 1/0.254 | 0.25 | 0.33 | 0.92 | 361 | 305 |
7/0.1 | 0.3 | 0.33 | 0.96 | 381.00 | ||
19/0.06 | 0.30 | 0.33 | 0.96 | 381.00 | ||
28 | 1/0.32 | 0.32 | 0.33 | 0.98 | 227.0 | 305 |
7/0.127 | 0.38 | 0.33 | 1.04 | 239.0 | ||
19/0.08 | 0.40 | 0.33 | 1.06 | 239.0 | ||
26 | 1/0.404 | 0.4 | 0.33 | 1.07 | 143.0 | 305 |
7/0.16 | 0.48 | 0.33 | 1.14 | 150.0 | ||
19/0.1 | 0.50 | 0.33 | 1.16 | 150 | ||
24 | 7/0.02 | 0.60 | 0.33 | 1.26 | 94.2 | 305 |
19/0.12 | 0.60 | 0.33 | 1.26 | 94.2 | ||
22 | 7/0.254 | 0.76 | 0.33 | 1.42 | 59.4 | 610 |
19/0.15 | 0.75 | 0.33 | 1.42 | 59.4 | ||
20 | 7/0.32 | 0.96 | 0.33 | 1.62 | 36.7 | 610 |
19/0.19 | 0.95 | 0.33 | 1.62 | 36.7 | ||
18 | 7/0.404 | 1.21 | 0.33 | 1.87 | 23.2 | 610 |
19/0.235 | 1.18 | 0.33 | 1.87 | 23.2 | ||
16 | 19/0.3 | 1.50 | 0.33 | 2.16 | 14.6 | 610 |
14 | 19/0.37 | 1.85 | 0.35 | 2.54 | 8.96 | 610 |
12 | 19/0.475 | 2.38 | 0.33 | 3.04 | 5.64 | 610 |
OEM Specification Are Also Welcome!
Main Product
Hot Product
Company Intruction
Certification
UL Certification
Ul cables | |||||||||||||
Teflon Wire | |||||||||||||
1330 | 1332 | 10518 | 10064 | 10588 | 1371 | 1375 | 1589 | ||||||
1723 | 1886 | 1331 | 1333 | 1591 | 1592 | 1887 | 1901 | ||||||
Single-conductor, thermoplastic insulation. | |||||||||||||
1007 | 1032 | 1185 | 1284 | 1571 | 1283 | 1672 | 1569 | ||||||
1015 | 10198 | 10070 | |||||||||||
Multiple-conductor, thermoplastic insulation. | |||||||||||||
2464 | 2468 | 2725 | 20276 | 2835 | |||||||||
Single-conductor, thermoset insulation. | |||||||||||||
3271 | 3321 | ||||||||||||
Automotive Wires | |||||||||||||
German Standard | |||||||||||||
FLR2X-B | FLRY11Y/FLR4G11Y | FLRY-A | FLRY-B | FLRYW-A | FLRYW-B | FLRYY/FLR4GY | |||||||
China Standard | |||||||||||||
QB-A/B/C/D | QFR | QVR | QVR-105 | ||||||||||
Japan Standard | |||||||||||||
AV | AVS | AVSS | AVSSX/AESSX | AVX/AEX | CAVS | ||||||||
America Standard | |||||||||||||
GPT | GXL | HDT | SXL | TWP | TXL |
More Test report (Rohs,Reach,Flame Retardant),Pls contact us
Test Equipment
Production Process
Overseas Exibition
Packing
FAQ
Q:Are you a factory or a trading company
A:ADS company is a professional cable manufacturer with 15 years production experience.
Q:What's your company MOQ
A:Our company has MOQ requirements, but we also accept small quantity.
Q:Whether these products quality assured?
A:Most of cables are certificated. Also, we have strict QC, all products are 100% tested before delivery. Quality is assured.
Q:Can you send a sample for us to test?
A:1.If we have it in stock and the amount is small, it is free.
2.If we do not have it in stock, sample and freight cost have have to be paid by your esteemed company. But we will return the sample cost to you when we receiving your initial order.
Q:If I want to purchase, how to pay?
A: Generally we do T/T in 30% deposit before production, 70% balance before loading. Also payment terms are negotiable depending on customer's request.
Contact Us
Nora (Sales manager)
Haiyan ADS Special Cable Co.,Ltd
Building 1-2, No.88 Huxi Street,Shiquan,Haiyan, Zhejiang, China,314300
Web:http://adscable.en.made-in-china.com.